New
UNI-T UTS3036B 3.6 GHz Performance-Series Spectrum Analyzer
Pickup available at Digilog Electronics
Usually ready in 2 hours
UNI-T UTS3036B 3.6 GHz Performance-Series Spectrum Analyzer
UNI-T UTS3036B 3.6 GHz Performance-Series Spectrum Analyzer
UNI-T UTS3036B — The UNI-T UTS3036B Performance-Series Spectrum Analyzer covers 9 kHz – 3.6 GHz with a 10.1-inch capacitive multi-touch display, a 1 Hz resolution-bandwidth floor, and up to 40,001 sweep points. It targets the sub-3.6 GHz bench measurement workload — communications module verification, IoT and wireless development, harmonic and spurious testing — with the option to add a tracking generator in the field when your work demands scalar transmission measurements. Genuine UNI-T product supplied by Digilog.pk with warranty.
Key Features
- 9 kHz – 3.6 GHz frequency coverage — sub-3.6 GHz for general RF dev, communications, harmonic surveys, and EMI pre-compliance work
- -161 dBm/Hz typical DANL — (preamp on) — sensitive enough to resolve low-level signals, spurs, and harmonic energy near the noise floor
- <-98 dBc/Hz phase noise @ 10 kHz offset — (typical, 1 GHz carrier) — clean enough for close-in spectral measurements and modulated-signal analysis
- 1 Hz – 3 MHz RBW — in 1-3-10 steps — fine resolution control all the way down to a 1 Hz floor, with FFT mode for faster narrowband sweeps
- 40,001 sweep points — deep trace detail (4× the count of UNI-T's entry tier) for catching signals that coarser analyzers miss
- 10.1-inch capacitive multi-touch display — (1280 × 800) — pinch, drag, and tap to set markers, with full mouse/keyboard support via USB
- Six traces with five detector modes — Sample, Peak, Negative, Normal, Average; Clear/Write, Average, Max Hold, Min Hold trace types
Technical Specifications
| Frequency Range | 9 kHz – 3.6 GHz |
|---|---|
| Displayed Average Noise Level (DANL) | -161 dBm/Hz (typical, preamp on) |
| Phase Noise | <-98 dBc/Hz @ 10 kHz offset (typical, 1 GHz carrier) |
| Amplitude Accuracy | <0.7 dB |
| Sweep Points (max) | 40,001 |
| Number of Traces | 6 |
| Detector Types | Sample, Peak, Negative, Normal, Average |
| Trace Types | Clear/Write, Average, Max Hold, Min Hold |
| Sweep Modes | Swept, FFT |
| Preamplifier | 20 dB (nominal), switchable |
| Input Attenuator Range | 0 – 51 dB, 1 dB steps |
| Reference Level Range | -100 dBm to +30 dBm |
| Maximum Safe Input | +33 dBm CW (3 min, attenuation >20 dB); 50 V DC max |
What's in the Box
- Power cord
- USB2.0 printing cable
- English download guide
- multi-language safety manual
- calibration report (COC)
Downloads
Certifications: CE, RoHS | HS Code: 9030.89
TRENDING
Top view in this week
1500mah 3.7v 18650 Li Ion Battery With Bms And Wire
Sale priceRs 180 PKR
12v Wifi Router Power Bank Without Adapter
Sale priceRs 1,000 PKR







