{"product_id":"uni-t-ut70a-digital-multimeter","title":"UNI-T UT70A Multi-Function Digital Multimeter – 2000 Count, AC\/DC 1000V, 10A, Inductance to 20H, Capacitance to 100µF, 10MHz Frequency, K-Type Temperature to 1000°C, hFE \u0026 TTL Logic","description":"\u003cp\u003e\u003cstrong\u003eUNI-T UT70A\u003c\/strong\u003e — a 2000-count \u003cstrong\u003emulti-function hand-held digital multimeter\u003c\/strong\u003e that reaches well beyond a standard DMM: alongside AC\/DC voltage and current it measures \u003cstrong\u003einductance to 20 H\u003c\/strong\u003e, capacitance to 100 µF, \u003cstrong\u003efrequency to 10 MHz\u003c\/strong\u003e, K-type temperature to 1000°C, transistor hFE and \u003cstrong\u003eTTL logic levels\u003c\/strong\u003e. With data hold, maximum-value hold, backlight and auto power-off, it is a capable single-instrument tool for electronics development and servicing. Genuine UNI-T product supplied by Digilog.pk with warranty.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2000-count\u003c\/strong\u003e 3½-digit LCD (max. reading 1999), 53 × 62 mm screen with backlight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductance 2 mH – 20 H\u003c\/strong\u003e and capacitance 20 nF – 100 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-range frequency 2 kHz – 10 MHz\u003c\/strong\u003e, ±(0.1%+3)\u003c\/li\u003e\n\u003cli\u003eResistance to \u003cstrong\u003e2000 MΩ\u003c\/strong\u003e; DC\/AC voltage to 1000 V \/ 750 V; DC\/AC current to 10 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK-type temperature −40°C to 1000°C\u003c\/strong\u003e; transistor hFE (0–1000β, NPN\/PNP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTTL logic test\u003c\/strong\u003e (high ≥2.0 V, low ≤0.8 V) with buzzer indication\u003c\/li\u003e\n\u003cli\u003eData hold, maximum-value hold, auto power-off after 15 minutes, full overload protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e2000 count (max. reading 1999, 3½ digits), 53 × 62 mm, backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Voltage\u003c\/th\u003e\n\u003ctd\u003e200 mV \/ 2 V \/ 20 V \/ 200 V ±(0.5%+1); 1000 V ±(0.8%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Voltage\u003c\/th\u003e\n\u003ctd\u003e200 mV ±(1.2%+3); 2 V \/ 20 V \/ 200 V ±(0.8%+3); 750 V ±(1.2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Voltage Bandwidth\u003c\/th\u003e\n\u003ctd\u003e40 Hz – 400 Hz (average responding, RMS of sine wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Impedance\u003c\/th\u003e\n\u003ctd\u003eApprox. 10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Current\u003c\/th\u003e\n\u003ctd\u003e20 µA \/ 2 mA ±(0.8%+1); 200 mA ±(1.5%+1); 10 A ±(2%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Current\u003c\/th\u003e\n\u003ctd\u003e20 µA \/ 2 mA ±(1%+3); 200 mA ±(1.8%+3); 10 A ±(3%+7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Current Input\u003c\/th\u003e\n\u003ctd\u003e10 A (≤10 s per measurement, ≥15 min between measurements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance\u003c\/th\u003e\n\u003ctd\u003e200 Ω – 2000 MΩ (7 ranges), best accuracy ±(0.8%+1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacitance\u003c\/th\u003e\n\u003ctd\u003e20 nF \/ 200 nF \/ 2 µF ±(2.5%+5); 100 µF ±(5%+4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInductance\u003c\/th\u003e\n\u003ctd\u003e2 mH \/ 20 mH \/ 200 mH ±(2%+10); 20 H ±(3%+10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInductance Test Conditions\u003c\/th\u003e\n\u003ctd\u003eQ ≥ 10, internal impedance ≤ 1.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e2 kHz – 10 MHz auto-range, 1 Hz resolution (min.), ±(0.1%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Input Sensitivity\u003c\/th\u003e\n\u003ctd\u003e≤0.8 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003e−40°C – 1000°C — ±(3%+4) from −40 to 0°C, ±(1%+3) from 0 to 400°C, ±(2%+10) from 400 to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTransistor hFE\u003c\/th\u003e\n\u003ctd\u003e0 – 1000β (NPN \/ PNP), Ibo approx. 10 µA, Vce approx. 2.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTTL Logic\u003c\/th\u003e\n\u003ctd\u003eLogic high ≥ 2.0 V, logic low ≤ 0.8 V, buzzer indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiode Test\u003c\/th\u003e\n\u003ctd\u003e1 mV resolution; open-circuit voltage approx. 2.8 V, forward current approx. 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuity\u003c\/th\u003e\n\u003ctd\u003eBuzzer sounds at \u0026lt;70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSampling Rate\u003c\/th\u003e\n\u003ctd\u003eApprox. 2.5 readings\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent Input Fuses\u003c\/th\u003e\n\u003ctd\u003eF 0.5 A \/ 250 V; F 10 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eCE version: IEC 61010-1, pollution degree 2, CAT III 1000V \/ CAT IV 600V, double insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e1 × 9 V battery (6F22 or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Conditions\u003c\/th\u003e\n\u003ctd\u003e5°C – 40°C; \u0026lt;80% RH at 5–31°C, \u0026lt;50% RH at 31–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e195 × 90 × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApprox. 600 g (including holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT70A multi-function digital multimeter\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest clips\u003c\/li\u003e\n\u003cli\u003eMulti-purpose socket\u003c\/li\u003e\n\u003cli\u003eEnglish operating manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE version: IEC 61010-1, CAT III 1000V \/ CAT IV 600V, double insulation  |  \u003cstrong\u003eHS Code:\u003c\/strong\u003e 9030.31\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":51575003939094,"sku":"UT70A","price":10000.0,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/digilog.pk\/products\/uni-t-ut70a-digital-multimeter","provider":"digilog.pk","version":"1.0","type":"link"}