{"product_id":"uni-t-ut52-digital-multimeter","title":"UNI-T UT52 Digital Multimeter – 2000 Count, AC\/DC 1000V, 20A, Capacitance to 20µF, Resistance to 200MΩ, Diode \u0026 Continuity, CAT III 300V","description":"\u003cp\u003e\u003cstrong\u003eUNI-T UT52\u003c\/strong\u003e — a 2000-count \u003cstrong\u003ehand-held digital multimeter\u003c\/strong\u003e from the UT50 series, adding \u003cstrong\u003ecapacitance measurement\u003c\/strong\u003e and a high \u003cstrong\u003e20 A\u003c\/strong\u003e current range over the entry UT51. Built around a dual-integral A\/D converter with full-range overload protection, it suits electrical, automotive and appliance work where higher current and capacitor testing are needed. Genuine UNI-T product supplied by Digilog.pk with warranty.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2000-count\u003c\/strong\u003e LCD (max. reading 1999, 3½ digits) with 27 mm digit height\u003c\/li\u003e\n\u003cli\u003eDC voltage \u003cstrong\u003e200 mV – 1000 V\u003c\/strong\u003e, AC voltage 200 mV – 750 V (40–400 Hz)\u003c\/li\u003e\n\u003cli\u003eDC and AC current to \u003cstrong\u003e20 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance 2 nF – 20 µF\u003c\/strong\u003e ±(4%+3) via a dedicated capacitance jack\u003c\/li\u003e\n\u003cli\u003eResistance \u003cstrong\u003e200 Ω – 200 MΩ\u003c\/strong\u003e, plus diode test and continuity buzzer\u003c\/li\u003e\n\u003cli\u003eIEC 61010 \u003cstrong\u003eCAT I 1000V \/ CAT II 600V \/ CAT III 300V\u003c\/strong\u003e, double insulation\u003c\/li\u003e\n\u003cli\u003eTilt stand with three viewing angles and carry strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e2000 count (max. reading 1999, 3½ digits), 27 mm digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Voltage\u003c\/th\u003e\n\u003ctd\u003e200 mV \/ 2 V \/ 20 V \/ 200 V ±(0.5%+1); 1000 V ±(0.8%+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Voltage\u003c\/th\u003e\n\u003ctd\u003e200 mV ±(1.2%+3); 2 V \/ 20 V \/ 200 V ±(0.8%+3); 750 V ±(1.2%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Voltage Bandwidth\u003c\/th\u003e\n\u003ctd\u003e40 Hz – 400 Hz (average responding, RMS of sine wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Impedance\u003c\/th\u003e\n\u003ctd\u003e10 MΩ (all voltage ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Current\u003c\/th\u003e\n\u003ctd\u003e2 mA \/ 20 mA ±(0.8%+1); 200 mA ±(1.5%+1); 20 A ±(2%+5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Current\u003c\/th\u003e\n\u003ctd\u003e2 mA ±(1%+3); 20 mA ±(1%+3); 200 mA ±(1.8%+3); 20 A ±(3%+7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Current Input\u003c\/th\u003e\n\u003ctd\u003e20 A (≤15 s per measurement, ≥15 min between measurements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance\u003c\/th\u003e\n\u003ctd\u003e200 Ω – 200 MΩ (7 ranges), best accuracy ±(0.8%+1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacitance\u003c\/th\u003e\n\u003ctd\u003e2 nF \/ 20 nF \/ 200 nF \/ 2 µF \/ 20 µF ±(4%+3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCapacitance Test Signal\u003c\/th\u003e\n\u003ctd\u003eApprox. 400 Hz, 40 mVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiode Test\u003c\/th\u003e\n\u003ctd\u003eForward DC current approx. 1 mA; open-circuit voltage approx. 2.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuity\u003c\/th\u003e\n\u003ctd\u003eBuzzer sounds at ≤70 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent Input Fuse\u003c\/th\u003e\n\u003ctd\u003e315 mA \/ 250 V, φ5×20 mm (no fuse on the 20 A range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eIEC 61010; CAT I 1000V, CAT II 600V, CAT III 300V; double insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e1 × 9 V battery (NEDA 1604 \/ 6F22 \/ 006P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Conditions\u003c\/th\u003e\n\u003ctd\u003e0°C – 40°C, ≤80% RH up to 31°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e190 × 88 × 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApprox. 270 g (meter only); approx. 550 g with holster and tilt stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT52 digital multimeter\u003c\/li\u003e\n\u003cli\u003eTest leads (1 pair)\u003c\/li\u003e\n\u003cli\u003eEnglish operating manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC 61010; CAT I 1000V, CAT II 600V, CAT III 300V; double insulation  |  \u003cstrong\u003eHS Code:\u003c\/strong\u003e 9030.31\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":51575003808022,"sku":"UT52","price":6000.0,"currency_code":"PKR","in_stock":true}],"url":"https:\/\/digilog.pk\/products\/uni-t-ut52-digital-multimeter","provider":"digilog.pk","version":"1.0","type":"link"}