The UNI-T UT595 multifunction installation tester brings a full electrical-installation test suite into one 9999-count instrument: insulation resistance at 250V, 500V and 1000V up to 1000MΩ, 200mA low-resistance continuity, line and loop impedance from 0.01Ω to 2000Ω with prospective fault current to 26kA, RCD trip-time and ramp testing, phase sequence and AC voltage to 440V.
The UT595 is the upper model of the UT590 series, extending RCD trip-time coverage with ×2 I△n test ranges. With connection checks displayed in real time, one-key storage of RCD results and a 0°/180° phase-angle option to catch the fastest trigger time, it is built for electrical contractors and inspectors certifying installations.
Key Features
- Insulation to 1000MΩ ⚡ — 250V / 500V / 1000V test voltages at ±10%, ±(5%+5) accuracy.
- 200mA continuity testing 🔧 — 0.00Ω~199Ω range with over 200mA test current for earth continuity.
- Loop and line impedance ✅ — 0.01Ω~2000Ω with 20A test current and PFC/PSC to 26kA.
- Non-trip loop impedance 🔧 — 1.00Ω~2000Ω at 15mA so you can test without tripping the RCD.
- Full RCD trip-time testing ⚡ — 10/30/100/300/500mA at ×1/2, ×1, ×2 and ×5 I△n, plus ramp testing.
- 0°/180° phase angle option ✅ — detect the fastest trigger time; half-wave and 30 s count-down modes.
- Phase sequence and missing-phase test 🔧 — 100V~440V, forward and reverse rotation display.
- 9999-count LCD with analogue bar 🔋 — white backlight, data storage and auto power-off.
Technical Specifications
| Insulation output voltage | 250V / 500V / 1000V — ±10% |
|---|---|
| Insulation resistance (250V) | 0.05MΩ~250MΩ — ±(5%+5) |
| Insulation resistance (500V) | 0.05MΩ~500MΩ — ±(5%+5) |
| Insulation resistance (1000V) | 0.05MΩ~1000MΩ — ±(5%+5) |
| Short-circuit current | under 2mA |
| Low-resistance continuity | 0.00Ω~199Ω — ±(2%+5); test current over 200mA (0.00~2Ω) |
| Line impedance | 0.01Ω~2000Ω — ±(5%+5); 230V (45Hz~65Hz); 20A test current; PFC 0kA~26kA |
| Loop impedance | 0.01Ω~2000Ω — ±(5%+5); 195V~253V (45Hz~65Hz); 20A test current; PFC 0kA~26kA |
| Non-trip loop impedance | 1.00Ω~2000Ω — ±(5%+5); 15mA test current; PFC 0kA~26kA |
| RCD test current | 10mA / 30mA / 100mA / 300mA / 500mA — ±10% |
| RCD trip time ×1/2 I△n | 0ms~2000ms — ±(5%+5) |
| RCD trip time ×1 I△n | 0ms~300ms (0ms~500ms with count down) — ±(5%+5) |
| RCD trip time ×2 I△n | 0ms~150ms (0ms~200ms with count down) — ±(5%+5) |
| RCD trip time ×5 I△n | 0ms~40ms — ±(5%+5) |
| Ramp RCD test | 10mA / 30mA / 100mA / 300mA / 500mA — ±10% |
| Phase sequence test | 100V~440V (45Hz~65Hz); forward and reverse rotation |
| AC voltage | 0V~440V — ±(5%+2); 45Hz~60Hz; resolution 1V |
| Display count | 9999 |
| RCD count down test | 30 s |
| Phase conversion (RCD) | 0° and 180° |
| Data storage | Yes |
| LCD backlight | Yes |
| Auto power off | Yes |
| Power | 1.5V battery (5# / AA) × 6 |
| LCD size | 125mm × 37mm |
| Product size | 210mm × 175mm × 90mm |
| Net weight | 1000g |
| Colour | Red and grey |
What's in the Box
- UT595 multifunction installation tester
- Test leads (red ×1, green ×1, black ×1)
- Special power test lead
- Remote-control test lead
- Batteries
- Manual, gift box and tool box
Downloads