MQ2 MQ-2 MQ 2 Smoke LPG Butane Hydrogen Gas Sensor Detector Module Smoke LPG Butane Hydrogen Gas Sensor Detector Module is useful for gas leakage detection (home and industry). It is suitable for detecting H2, LPG, CH4, CO, Alcohol, Smoke or Propane. Due to its high sensitivity and fast response time, measurement can be taken as soon as possible. The sensitivity of the sensor can be adjusted by potentiometer.

MQ-2 gas sensor using gas sensitive material is to be clean air in the lower conductivity of Tin oxide (SnO2). When the sensor when flammable gases are present in the environment in which the sensors conductivity with increasing concentration of combustible gas in the air increases. Use a simple circuit to convert the changes in conductivity and output signal that corresponds to the concentration of the gas.

MQ-2 gas sensor higher sensitivity to liquefie d petroleum gas, propane, hydrogen, detection of gas and other combustible vapors are ideal. This sensor can detect a variety of flammable gas, is a low-cost sensors for many applications.

Character Configuration:

  1. Good sensitivity to Combustible gas in wide range
  2. High sensitivity to LPG, Propane and Hydrogen
  3. Long life and low cost
  4. Simple drive circuit

Application:

  1. Domestic gas leakage detector
  2. Industrial Combustible gas detector
  3. Portable gas detector

Electronic Characteristics:

Items Parameter name Min Type Max Unit
System Characteristics
VCC Working Voltage 4.9 5 5.1 V
PH Heating consumption 0.5 800 mW
RL Load resistance can adjust
RH Heater resistance 33 Ω
Rs Sensing Resistance 3 30


Following conditions must be avoided:

Water Condensation
Indoor conditions, slight water condensation will effect sensors performance lightly. However, if water condensation on sensors surface and keep a certain period, sensor’ sensitivity will be decreased.

Used in high gas concentration
No matter the sensor is electrified or not, if long time placed in high gas concentration, if will affect sensors characteristic.

Long time storage
The sensors resistance produce reversible drift if it’s stored for long time without electrify, this drift is related with storage conditions. Sensors should be stored in airproof without silicon gel bag with clean air. For the sensors with long time storage but no electrify, they need long aging time forstbility before using.

Long time exposed to adverse environment
No matter the sensors electrified or not, if exposed to adverse environment for long time, such as high humidity, high temperature, or high pollution etc, it will effect the sensors performance badly.

Vibration
Continual vibration will result in sensors down-lead response then repture. In transportation or assembling line, pneumatic screw driver/ultrasonic welding machine can lead this vibration.

Concussion
If sensors meet strong concussion, it may lead its lead wire disconnected.

Package Includes:

1 x MQ-2 Smoke LPG Butane Hydrogen Gas Sensor Detector Module

Specifications and Features:

  1. Dimensions: 36 x 20 x 21 mm(LxWxH)
  2. Weight:8 gm
  3. Operating Voltage is +5V
  4. Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO and even methane
  5. Analog output voltage: 0V to 5V
  6. Digital Output Voltage: 0V or 5V (TTL Logic)
  7. Preheat duration 20 seconds
  8. Can be used as a Digital or analog sensor
  9. The Sensitivity of Digital pin can be varied using the potentiometer

Attachments and Links:

MQ-2 Datasheet: