Fluke 789 ProcessMeter the Ultimate Loop Calibration Multimeter+ Fast Shipping
The F789 Fluke Process Multimeter is the first process multimeter to combine a digital multimeter and a loop calibrator, doubling the capabilities of process technicians. Fluke has now introduced a new and better model, the Fluke 789 Loop Calibration Multimeter. The Fluke 789 has a 24V loop power supply and does not require separate carrying of loop power for offline transmitter testing; the built-in optional 250 Ω HART loop resistor eliminates the need to carry the load resistor alone. Fluke 789 lets you carry less and finish more.
Features:
24 V loop power supply
Double display large screen
Enhanced backlight, 2-level brightness adjustable
1200 Ohm drive capability with mA output
HART mode with loop power supply, built-in 250 ohm resistor
The 0% and 100% buttons toggle between the 4 and 20 mA outputs for quick full-scale inspection
Battery compartment door for easy battery replacement
Fluke 789 contains all features that the Fluke 787 has
Precision 1000 V, 440 mA True RMS Digital Multimeter
0.1% DC Voltage Accuracy
0.05% DC Current Accuracy
Up to 20 kHz frequency measurement
Min/Max/Avg/Contact Hold/Relative Mode
Diode test function and on-off buzzer
Simultaneous reading of mA readings and percentage readings
20 mA DC Current Output / Loop Calibrator / Simulator
Manual stepping (25%, coarse adjustment, fine adjustment), automatic stepping and automatic ramping
Battery compartment door for easy battery replacement
Current measurement | Range: 0-1 A AC or DC Resolution: 1 mA Accuracy: 0.2% + 2 LSD (DC) The Range: 0-30 mA Resolution: 0.001 mA Accuracy: 0.05% + 2 least significant digits | |||
Output current | Range: 0-20 mA or 4-20 mA Resolution: 0.05% full scale Drive capability: 24 V or 1200 Ω @ 20 mA | |||
Frequency | To 19.999 kHz, 0.005% + 1 least significant bit | |||
Continuity |
Beep at impedance <100 Ω |
| ||
Voltage measurement | Range: 0-1000 V AC (true rms) or DC Resolution: 0.1 mV to 1.0 V Accuracy: 0.1% reading + 1 least significant bit (VDC) |
| ||
Resistance measurement |
Up to 40 MΩ, 0.2% + 1 least significant bit | |||
Diode test |
2.0 V display diode voltage drop | |||
Shows the percentage of current and full scale | Yes | |||
Automatic stepping, automatic slope | Yes |
Environmental parameters: | |||
Operating temperature |
| ||
Storage temperature |
-40 C to 60 C | ||
Humidity (non-condensing) |
95% to 30 C 75% to 40 C 45% to 50 C 35% to 55 C | ||
Temperature Coefficient |
0.05 x (Nominal Accuracy) /oC (When Temperature < 18 C or > 28 C) |
Safety technical parameters | |||
Electrical Safety |
| ||
Overvoltage category | IEC 1010-1 CAT III 1000 V IEC 1010-1 CAT IV 600 V | ||
Maximum voltage |
1000 V RMS |
Mechanical and general parameters | |||
Dimensions | 50 x 100 x 203 mm | ||
Weight | 600 g | ||
Batteries |
4 AA alkaline batteries | ||
warranty period | 3 years | ||
Battery Life |
140 hours, typical value (measurement); 10 hours, typical value (output 20 mA) Vibration and vibration | ||
Vibration and vibration |
Random, 2 g, 5-500 Hz 1 meter drop test |
Model Name | Description |
Fluke 789 | Process Multimeter AC72 alligator clip Four AA Models 1.5 V Alkaline Batteries (Installed) Not included package TL71 Safety Design Test Lead Set User Manual and Quick Reference Guide |